Gst Intelligent Reflective Beam Detector (i-9105r) Addressable Alarm Gst Intelligent Reflective Beam Detector (i-9105r) Addressable Alarm Gst Intelligent Reflective Beam Detector (i-9105r) Addressable Alarm Gst Intelligent Reflective Beam Detector (i-9105r) Addressable Alarm Gst Intelligent Reflective Beam Detector (i-9105r) Addressable Alarm

Gst Intelligent Reflective Beam Detector (i-9105r) Addressable Alarm

SKU #4993609957412

Type: Smoke & Carbon Monoxide Detectors

Availability: In Stock

Prices starting from: $ 334.79

FREE TRACKED SHIPPING WORLDWIDE

Overview:
I-9105R Intelligent Reflective Beam Detector (the detector) is an addressable reflective infrared beam smoke detector that has two signal output ways: loop output and contact output. When the detector is connected with GST fire alarm control panel directly, state information will be transmitted through loop between the detector and the control panel. The detector can be programmed by GST programmer. Code range is within 1~242. When the detector is not connected with the control panel, fire and fault information can be transmitted by contacts.
The detector must be used together with a reflector. The number of reflector(s) to be used (one or four) depends on the distance from the detector.
With excellent built-in microprocessor, the detector has strong ability of analysis and judgment. The detector can carry out system adjustment, compensation of variation of ambient data, and judgment of fire and fault through fixed algorithm. With new and reasonable design, esthetical pleasing, flexible judgment and alignment method, it’s easy to install and adjust. The sensitivity of the detector can be set through hand held programmer in field, decreasing the demand for cleanliness of field conditions, and enlarging application areas.
The detector is applicable to historical buildings, warehouses, large storages, shopping malls, leisure centers, exhibition halls, hotel lobbies, printing houses, clothing factories, museums and prisons, as well as places where slight smoke particles.

Features
1. Wide operating voltage range, big monitoring areas.
2. Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.
3. Built-in microprocessor enables intelligent judgment about fire alarm and fault.
4. The detector can calibrate automatically, which ensures a single person complete adjustment in short time. It’s also convenient to operate.
5. Self-diagnosis function can monitor the inner fault.
6. Automatic compensation for factors weakening received signals, such as a certain of dust contamination, positional excursion and ageing transmitter.
7. Simple to control and operate by integrating digital bus protocol.
8. Electronically addressed. The address can be programmed in field.
9. Two sensitivity levels can be set in field.
10. The detector’s optical pathway is designed with strong anti-interference ability.
11. SMT processing technology.
12. Attractive and decent appearance.
13. Standard: EN 54-12.


Specifications:
1. Operating Voltage: 24VDC (15V~28V)Technical Specifications

2. Operating Current:
Power current: Commission current ?20mA
Standby current ?12mA
Alarm current ?22mA
3. Loop Output:
Loop Voltage: 24V (15V~28V)
4. Fire, fault contact output
Fire output contact: contact capacity is 28V/2A. Normally open in normal state, closed in fire condition.
Fault output contact: contact capacity is 28V/2A. Closed in normal state, and open in fault condition.
5. Angle of Adjusting: -6°?+6°
6. Maximum angular misalignment: ±0.5°
7. Sensitivity Level:
Level 1: 1.61dB
Level 2: 2.31dB
8. Indication of Detector State:
Commission: Green LED and yellow LED are lit or flashed in a certain way. Refer to details in Section VI Commission.
Normal monitoring state: Red LED flashes periodically.
Fire: Red LED illuminates when the detector reports fire alarm. Fire output contact is closed. The fire signal can be transmitted to the control panel through loop and has to be cleared by the control panel. Power on the detector again to clear the fire signal if GST control panel is not connected.

Fault: Yellow LED illuminates. Fault output contact is open. The detector clears the fault signal automatically if the condition causing the fault disappears.
Optical pathway obscured totally: the detector first gives fault signal and turns on yellow LED. 15 second later, it reports fire alarm, and red LED is turned on; fire output contact is closed. Yellow LED is turned off, fault output contact is closed. Note: In this case, it does not necessarily mean there is a fire. After the obscuration is removed, the detector clears the fault signal automatically. If fault signal turns to fire signal, it has to be cleared by the control panel or cutting off power.
9. Operating Environment:
Temperature: -10?C?+50?C
Relative Humidity?95%, non condensing
10. Monitoring Area: Maximum monitoring area: 14×100?1400m2
Maximum width: 14m
11. Length of Optical Pathway: 8m?100m
12. Ingress Protection Rating:
It is IP20 in ordinary environment; it is IP66 through glue-seal treatment in special environment.
13. Dimensions:
Length: 206mm Width: 95mm Depth: 95mm
14. Material and Color of Enclosure: ABS, gray
15. Weight: 450g
16. Mounting Hole Spacing:
Spacing for embedding: 158mm
Spacing for surface mounting: 79mm×96mm